Our office is in Marrickville, so the Inner West is home ground: site classifications, geotechnical investigations and footing inspections from Burwood to Newtown. Tight yards, old fill and established trees come up often here. This is what we found on our own jobs. Each result belongs to its site, so send us your address and we will read yours.

Site classifications from $800 + GST · Footing inspections from $600 + GST · Fixed fee in writing within one business day · 5.0 from 33 Google reviews

01 · Recent Jobs

What We Found, Job By Job.

SFGEO 4WD-mounted rig set up on a Burwood driveway, the operator in hi-vis at the controls

Driveway Rig · Burwood

Geotechnical Investigation

A Basement Behind A Heritage House

Burwood · basement pavilion and pool behind a heritage-listed home

The brief. A basement of about 325 square metres under a new rear pavilion, with a pool beside it, behind a heritage-listed house that stays. The bulk excavation runs 2.9 to 3.6 metres below the existing ground, near a sewer main.

On the ground. Four hand-auger holes inside the footprint and a rig borehole beside the house, each with a penetrometer test. The soil cover was thin: fill or topsoil over stiff residual clay, with extremely weathered material or rock from 0.1 to 0.7 metres within the footprint and weathered bedrock from 1.6 metres beside the house.

The outcome. The bulk excavation sits within weathered bedrock. The report gave the design team parameters for the foundations, the excavation and its support, the pool, and the protection of the sewer and the retained house.

4 hand augers + 1 rig borehole + 5 DCPs · Basement in weathered bedrock · Class M outside it

Penetrometer standing in an open footing trench beside a brick party wall at Newtown

Footing Trench · Newtown

Footing Inspection

Two Visits, Every Footing Tested

Newtown · alterations and additions

First visit. An internal pad footing was checked against the 150 kPa on the structural drawings, with a penetrometer test at its base, and passed.

Second visit. A footing beam and the rear footing, founded in high-plasticity residual clay with ironstone gravel. The top 200 millimetres at two test points was not adequately compacted; the contractor recompacted it while we watched, and it was reassessed before the footings were passed.

2 inspections · Penetrometer at every location tested · 150 kPa confirmed

Tape measure run along a brick-paved courtyard in Marrickville to a small test hole, old timber sleepers beside it

Courtyard · Marrickville

Site Classification

A Two-Storey Addition Beside A Retained Tree

Marrickville · rear addition to a semi-detached house

The brief. A two-storey rear addition built against the common wall, with a large tree to stay about five metres behind it. The report also covered the tree's influence on the footings.

On the ground. A hand-auger borehole and two penetrometer tests. About 0.45 metres of fill over residual silty clay, high then medium plasticity, stiff to very stiff, to hand-auger refusal at 1.6 metres. Towards the tree, one penetrometer met very low resistance to a metre, and that ground is treated as unsuitable for footings.

The outcome. Class P, because the retained tree stands within influence distance of the rear of the addition. The footings are designed on a Class H1 basis, with the tree provided for under AS 2870 Appendix H.

1 hand-auger borehole + 2 DCPs · Class P on an H1 basis · Tree influence assessed

02 · Services

What We Do Here.

Site Classification

AS 2870 site classifications for extensions, terraces and granny flats.

Geotechnical Investigations

Investigations to AS 1726 for DAs, CDCs, basements and heritage alterations.

Construction Phase Support

Footing and pier inspections from $600 + GST, up to the last one before the pour.

Tight Access

Motorised hand augers carry through a standard doorway or side passage, so courtyards and rear yards can be investigated without vehicle access.

Testing

Dynamic cone penetrometer testing, and NATA-accredited laboratory testing where the design calls for it.